Produkto aprašymas
| KEB COMBIVERT F5 -BASIC- | |||||||
| 230V | P | U | IN | nom.-/ max.- switch. frequ. |
|||
| A- housing | (kW) | (V) | (A) | (kHz) | |||
| 05.F5.B0A-690A | 0.37 | 1 x 200… 240 | 2.3 | 4 / 8 | |||
| 07.F5.B0A-6A0A | 0.75 | 1 x 200… 240 | 4 | 8 | |||
| 05.F5.B3A-090A | 0.37 | 1 x 200… 240 | 2.3 | 4 / 8 | |||
| 07.F5.B3A-0A0A | 0.75 | 1 x 200… 240 | 4 | 8 | |||
| B-; D- and E- housing | |||||||
| 07.F5.B1B-2B0A | 0.75 | 1/3 x 200… 240 | 4 | 16 | |||
| 09.F5.B1B-2B0A | 1.5 | 1/3 x 200… 240 | 7 | 16 | |||
| 10.F5.B1B-2A0A | 2.2 | 1/3 x 200… 240 | 10 | 8 / 16 | |||
| 12.F5.B1D-1A0A | 4 | 3 x 200… 240 | 16.5 | 8 / 16 | |||
| 13.F5.B1E-160A | 5.5 | 3 x 200… 240 | 24 | 8 / 16 | |||
| 14.F5.B1E-150A | 7.5 | 3 x 200… 240 | 33 | 4 / 16 | |||
| 400V | |||||||
| A- housing | |||||||
| 05.F5.B3A-390A | 0.37 | 3 x 380… 480 | 1.3 | 4 | |||
| 07.F5.B3A-390A | 0.75 | 3 x 380… 480 | 2.6 | 4 | |||
| 09.F5.B3A-390A | 1.5 | 3 x 380… 480 | 4.1 | 4 | |||
| B- housing | |||||||
| 05.F5.B1B-3B0A | 0.37 | 3 x 380… 480 | 1.3 | 16 | |||
| 07.F5.B1B-3B0A | 0.75 | 3 x 380… 480 | 2.6 | 16 | |||
| 09.F5.B1B-3A0A | 1.5 | 3 x 380… 480 | 4.1 | 8 / 16 | |||
| 10.F5.B1B-3A0A | 2.2 | 3 x 380… 480 | 5.8 | 8 / 16 | |||
| 12.F5.B1B-350A | 4 | 3 x 380… 480 | 9.5 | 4 | |||
| D- housing | |||||||
| 12.F5.B1D-3A0A | 4 | 3 x 380… 480 | 9.5 | 8 / 16 | |||
| 13.F5.B1D-390A | 5.5 | 3 x 380… 480 | 12 | 4 / 16 | |||
| 14.F5.B1D-380A | 7.5 | 3 x 380… 480 | 16.5 | 2 | |||
| E- housing | |||||||
| 12.F5.B1E-3B0A | 4 | 3 x 380… 480 | 9.5 | 16 | |||
| 13.F5.B1E-3B0A | 5.5 | 3 x 380… 480 | 12 | 16 | |||
| 14.F5.B1E-3A0A | 7.5 | 3 x 380… 480 | 16 | 8 / 16 | |||
| 15.F5.B1E-350A | 11 | 3 x 380… 480 | 24 | 4 / 16 | |||
| 16.F5.B1E-340A | 15 | 3 x 380… 480 | 33 | 2 | |||
| KEB COMBIVERT F5 -COMPACT- | |||||||
| B- … R- housing | P | U | IN | nom.-/ max.- switch. frequ. |
|||
| 230V | (kW) | (V) | (A) | (kHz) | |||
| 05.F5.C1B-2B0A | 0.37 | 1/3 x 200… 240 | 2.3 | 16 | |||
| 07.F5.C1B-2B0A | 0.75 | 1/3 x 200… 240 | 4 | 16 | |||
| 09.F5.C1B-2B0A | 1.5 | 1/3 x 200… 240 | 7 | 16 | |||
| 10.F5.C1B-2A0A | 2.2 | 1/3 x 200… 240 | 10 | 8 / 16 | |||
| 12.F5.C1D-1A0A | 4 | 3 x 200… 240 | 16.5 | 8 / 16 | |||
| 13.F5.C1E-160A | 5.5 | 3 x 200… 240 | 24 | 8 / 16 | |||
| 14.F5.C1E-150A | 7.5 | 3 x 200… 240 | 33 | 4 / 16 | |||
| 15.F5.C1G-190F | 11 | 3 x 200… 240 | 48 | 4 / 16 | |||
| 16.F5.C1H-1B0F | 15 | 3 x 200… 240 | 66 | 16 | |||
| 400V | |||||||
| 05.F5.C1B-3B0A | 0.37 | 3 x 380… 480 | 1.3 | 16 | |||
| 07.F5.C1B-3B0A | 0.75 | 3 x 380… 480 | 2.6 | 16 | |||
| 09.F5.C1B-3A0A | 1.5 | 3 x 380… 480 | 4.1 | 8 / 16 | |||
| 10.F5.C1B-3A0A | 2.2 | 3 x 380… 480 | 5.8 | 8 / 16 | |||
| 12.F5.C1B-350A | 4 | 3 x 380… 480 | 9.5 | 4 | |||
| 12.F5.C1D-3A0A | 4 | 3 x 380… 480 | 9.5 | 8 / 16 | |||
| 13.F5.C1D-390A | 5.5 | 3 x 380… 480 | 12 | 4 / 16 | |||
| 14.F5.C1D-380A | 7.5 | 3 x 380… 480 | 16.5 | 2 / 16 | |||
| 12.F5.C1E-3B0A | 4 | 3 x 380… 480 | 9.5 | 16 | |||
| 13.F5.C1E-3B0A | 5.5 | 3 x 380… 480 | 12 | 16 | |||
| 14.F5.C1E-3A0A | 7.5 | 3 x 380… 480 | 16.5 | 8 / 16 | |||
| 15.F5.C1E-350A | 11 | 3 x 380… 480 | 24 | 4 / 16 | |||
| 16.F5.C1E-340A | 15 | 3 x 380… 480 | 33 | 2 / 16 | |||
| 15.F5.C1G-360A | 11 | 3 x 380… 480 | 24 | 8 / 16 | |||
| 16.F5.C1G-360A | 15 | 3 x 380… 480 | 33 | 8 / 16 | |||
| 17.F5.C1G-350A | 18.5 | 3 x 380… 480 | 42 | 4 / 16 | |||
| 18.F5.C1G-340F | 22 | 3 x 380… 480 | 50 | 2 / 8 | |||
| 17.F5.C0H-360F | 18.5 | 3 x 380… 480 | 42 | 16 | |||
| 18.F5.C0H-360F | 22 | 3 x 380… 480 | 50 | 8 / 16 | |||
| 19.F5.C0H-350F | 30 | 3 x 380… 480 | 60 | 4 / 16 | |||
| 20.F5.C0H-340F | 37 | 3 x 380… 480 | 75 | 2 / 8 | |||
| 19.F5.C0R/C2R-960A | 30 | 3 x 380… 480 | 60 | 8 / 16 | |||
| 20.F5.C0R/C2R-960A | 37 | 3 x 380… 480 | 75 | 8 / 16 | |||
| 21.F5.C0R/C2R-950A | 45 | 3 x 380… 480 | 90 | 4 / 16 | |||
| 22.F5.C0R/C2R-950A | 55 | 3 x 380… 480 | 115 | 4 / 16 | |||
| 23.F5.C0R/C2R-940A | 75 | 3 x 380… 480 | 150 | 2 / 12 | |||
| 24.F5.C0R-940A | 90 | 3 x 380… 480 | 180 | 2 / 8 | |||
| KEB COMBIVERT F5 | |||||||
| F5 – A – SERVO | |||||||
| UN | IN | Imax | |||||
| ( V AC) | ( A ) | ( A ) | |||||
| 05.F5.A1A-2E2F | 1/3 x 200… 240 | 2.3 | 4;6 | ||||
| 07.F5.A1A-3E2F | 3 x 380… 480 | 2.6 | 5;2 | ||||
| 07.F5.A1A-2E2F | 1/3 x 200… 240 | 4 | 8 | ||||
| 09.F5.A1A-3D2F | 3 x 380… 480 | 4.1 | 8;2 | ||||
| 00.90.034-0004 | 24V DC – power supply wall transformer (1 A) for control board | ||||||
| 00.58.010-AF5S | F5-Servo adapter for KEB Multi Operator 00.58.010-G000 | ||||||
| F5 – GENERAL / MULTI / SERVO | |||||||
| D- … H- housing | P | U | IN | nom.-/ max.- switch. frequ. |
|||
| (kW) | (V) | (A) | (kHz) | ||||
| 07.F5.A1D-2B0A | 0.75 | 1/3 x 200… 240 | 4 | 16 | |||
| 09.F5.A1D-2B0A | 1.5 | 1/3 x 200… 240 | 7 | 16 | |||
| 10.F5.A1D-2B0A | 2.2 | 1/3 x 200… 240 | 10 | 16 | |||
| 12.F5.A1D-1A0A | 4 | 3 x 200… 240 | 16.5 | 8 / 16 | |||
| 13.F5.A1E-160A | 5.5 | 3 x 200… 240 | 24 | 8 / 16 | |||
| 14.F5.A1E-150A | 7.5 | 3 x 200… 240 | 33 | 4 / 16 | |||
| 15.F5.A1G-190F | 11 | 3 x 200… 240 | 48 | 4 / 16 | |||
| 16.F5.A1H-1B0F | 15 | 3 x 200… 240 | 66 | 16 | |||
| 07.F5.A1D-3B0A | 0.75 | 3 x 380… 480 | 2.6 | 16 | |||
| 09.F5.A1D-3A0A | 1.5 | 3 x 380… 480 | 4.1 | 8 / 16 | |||
| 10.F5.A1D-3A0A | 2.2 | 3 x 380… 480 | 5.8 | 8 / 16 | |||
| 12.F5.A1D-3A0A | 4 | 3 x 380… 480 | 9.5 | 8 / 16 | |||
| 13.F5.A1D-390A | 5.5 | 3 x 380… 480 | 12 | 4 / 16 | |||
| 14.F5.A1D-380A | 7.5 | 3 x 380… 480 | 16 | 2 / 16 | |||
| 13.F5.A1E-3B0A | 5.5 | 3 x 380… 480 | 12 | 16 | |||
| 14.F5.A1E-3A0A | 7.5 | 3 x 380… 480 | 16 | 8 / 16 | |||
| 15.F5.A1E-350A | 11 | 3 x 380… 480 | 24 | 4 / 16 | |||
| 16.F5.A1E-340A | 15 | 3 x 380… 480 | 33 | 2 / 16 | |||
| 16.F5.A1G-360A | 15 | 3 x 380… 480 | 33 | 8 / 16 | |||
| 17.F5.A1G-350A | 18.5 | 3 x 380… 480 | 42 | 4 / 16 | |||
| 18.F5.A1G-340F | 22 | 3 x 380… 480 | 50 | 2 / 8 | |||
| H-… W- housing | P | U | IN | nom.-/ max.- switch. frequ. |
|||
| part no. | (kW) | (V) | (A) | (kHz) | |||
| 18.F5.A1H-360F | 22 | 3 x 380… 480 | 50 | 8 / 16 | |||
| 18.F5.A0H-360F | |||||||
| 19.F5.A1H-350F | 30 | 3 x 380… 480 | 60 | 4 / 16 | |||
| 19.F5.A0H-350F | |||||||
| 20.F5.A1H-340F | 37 | 3 x 380… 480 | 75 | 2 / 8 | |||
| 20.F5.A0H-340F | |||||||
| 20.F5.A1/3R-960A | 37 | 3 x 380… 480 | 75 | 8 / 16 | |||
| 20.F5.A0R/A2R-960A | |||||||
| 21.F5.A1/3R-950A | 45 | 3 x 380… 480 | 90 | 4 / 16 | |||
| 21.F5.A0R/A2R-950A | |||||||
| 22.F5.A1/3R-950A | 55 | 3 x 380… 480 | 115 | 4 / 16 | |||
| 22.F5.A0R/A2R-950A | |||||||
| 23.F5.A1/3R-94xA | 75 | 3 x 380… 480 | 150 | 2 / 12 | |||
| 23.F5.A0R/A2R-940A | |||||||
| 23.F5.A1U-96xA | 75 | 3 x 380… 480 | 150 | 8 | |||
| 23.F5.A0U-960A | |||||||
| 24.F5.A1R-94xA | 90 | 3 x 380… 480 | 180 | 2 / 8 | |||
| 24.F5.A0R-940A | |||||||
| 24.F5.A1U-95xA | 90 | 3 x 380… 480 | 180 | 4 / 16 | |||
| 24.F5.A0U-950A | |||||||
| 25.F5.A1U-91xA | 110 | 3 x 380… 480 | 210 | 4 / 8 | |||
| 25.F5.A0U-910A | |||||||
| 26.F5.A1U-91xA | 132 | 3 x 380… 480 | 250 | 4 / 8 | |||
| 26.F5.A0U-910A | |||||||
| 27.F5.A1U-90xA | 160 | 3 x 380… 480 | 300 | 2 / 8 | |||
| 27.F5.A0U-900A | |||||||
| 28.F5.A1W-90xA | 200 | 3 x 380… 480 | 370 | 2 / 4 | |||
| 28.F5.A0W-900A | |||||||
| 29.F5.A1W-90xA | 250 | 3 x 380… 480 | 460 | 2 | |||
| 29.F5.A0W-900A | |||||||
| 30.F5.A1W-A0xA | 315 | 3 x 380… 480 | 570 | 2 | |||
| 30.F5.A0W-A00A | |||||||
| 31.F5.A1W-A0xD | 355 | 3 x 380… 480 | 630 | 2 | |||
| 31.F5.A0W-A00D | |||||||
| 32.F5.A1W-A0xD | 400 | 3 x 380… 480 | 710 | 2 | |||
| 32.F5.A0W-A00D | |||||||
| P- housing | P | In | moduls | fs | |||
| (kW) | (A) | ||||||
| (kW) | (A) | (kHz) | |||||
| 28.F5.A1P-900A/H | 200 | 370 | 1 | 2 / 4 | |||
| 28.F5.A0P-900A/H | |||||||
| 29.F5.A1P-900D/H | 250 | 460 | 1 | 2 / 4 | |||
| 29.F5.A0P-900D/H | |||||||
| 30.F5.A1P-900H | 315 | 570 | 1 | 2 / 4 | |||
| 30.F5.A0P-900H | |||||||
| 33.F5.A1P-900D/H | 450 | 800 | 2 | 2 / 4 | |||
| 33.F5.A0P-900D/H | |||||||
| 34.F5.A1P-900D/H | 500 | 890 | 2 | 2 / 4 | |||
| 34.F5.A0P-900D/H | |||||||
| 35.F5.A1P-900D/H | 560 | 1000 | 2 | 2 / 4 | |||
| 35.F5.A0P-900D/H | |||||||
| 36.F5.A1P-900D/H | 630 | 1150 | 3 | 2 / 4 | |||
| 36.F5.A0P-900D/H | |||||||
| 37.F5.A1P-900D/H | 710 | 1330 | 3 | 2 | |||
| 37.F5.A0P-900D/H | |||||||
| 38.F5.A1P-900H | 800 | 1450 | 3 | 2 | |||
| 38.F5.A0P-900H | |||||||
| 28.F5.A1P-B00A/H | 200 | 225 | 1 | 2 | |||
| 28.F5.A0P-B00A/H | |||||||
| 29.F5.A1P-B00D/H | 250 | 280 | 1 | 2 | |||
| 29.F5.A0P-B00D/H | |||||||
| 30.F5.A1P-B00H | 315 | 345 | 1 | 2 | |||
| 30.F5.A0P-B00H | |||||||
| 30.F5.A1P-B00A | 315 | 345 | 2 | 2 | |||
| 30.F5.A0P-B00A | |||||||
| 32.F5.A1P-B00A/H | 400 | 430 | 2 | 2 | |||
| 32.F5.A0P-B00A/H | |||||||
| 33.F5.A1P-B00D/H | 450 | 500 | 2 | 2 | |||
| 33.F5.A0P-B00D/H | |||||||
| 34.F5.A1P-B00D/H | 500 | 550 | 2 | 2 | |||
| 34.F5.A0P-B00D/H | |||||||
| 35.F5.A1P-B00D/H | 560 | 620 | 2 | 2 | |||
| 35.F5.A0P-B00D/H | |||||||
| 36.F5.A1P-B00A/H | 630 | 710 | 3 | 2 | |||
| 36.F5.A0P-B00A/H | |||||||
| 37.F5.A1P-B00D/H | 710 | 820 | 3 | 2 | |||
| 37.F5.A0P-B00D/H | |||||||
| 38.F5.A1P-B00D/H | 800 | 900 | 3 | 2 | |||
| 38.F5.A0P-B00D/H | |||||||
| 39.F5.A1P-B00H | 900 | 1000 | 3 | 2 | |||
| 39.F5.A0P-B00H | |||||||
| KEB COMBIVERT F5-K with STO | |||||||
| D- … H- housing | P | U | In | nom.-/ max.- switch. frequ. |
|||
| (kW) | (V) | (A) | (kHz) | ||||
| 09.F5.K1D-2B0A | 1;5 | 1/3 x 200… 240 | 7 | 16 | |||
| 10.F5.K1D-2B0A | 2;2 | 1/3 x 200… 240 | 10 | 16 | |||
| 12.F5.K1D-1A0A | 4 | 3 x 200… 240 | 16;5 | 8 / 16 | |||
| 13.F5.K1E-160A | 5;5 | 3 x 200… 240 | 24 | 8 / 16 | |||
| 14.F5.K1E-150A | 7;5 | 3 x 200… 240 | 33 | 4 / 16 | |||
| 15.F5.K1G-190F | 11 | 3 x 200… 240 | 48 | 4 / 16 | |||
| 16.F5.K1H-1B0F | 15 | 3 x 200… 240 | 66 | 16 | |||
| 09.F5.K1D-3A0A | 1;5 | 3 x 380… 480 | 4;1 | 8 / 16 | |||
| 10.F5.K1D-3B0A | 2;2 | 3 x 380… 480 | 5;8 | 16 | |||
| 12.F5.K1D-3A0A | 4 | 3 x 380… 480 | 9;5 | 8 / 16 | |||
| 13.F5.K1D-390A | 5;5 | 3 x 380… 480 | 12 | 4 / 16 | |||
| 14.F5.K1D-380A | 7;5 | 3 x 380… 480 | 16 | 2 / 16 | |||
| 13.F5.K1E-3B0A | 5;5 | 3 x 380… 480 | 12 | 16 | |||
| 14.F5.K1E-3A0A | 7;5 | 3 x 380… 480 | 16 | 8 / 16 | |||
| 15.F5.K1E-350A | 11 | 3 x 380… 480 | 24 | 4 / 16 | |||
| 16.F5.K1E-340A | 15 | 3 x 380… 480 | 33 | 2 / 16 | |||
| 16.F5.K1G-360A | 15 | 3 x 380… 480 | 33 | 8 / 16 | |||
| 17.F5.K1G-350A | 18;5 | 3 x 380… 480 | 42 | 4 / 16 | |||
| 18.F5.K1G-340F | 22 | 3 x 380… 480 | 50 | 2 / 8 | |||
| H-… W- housing | |||||||
| 18.F5.K1H-360F | 22 | 3 x 380… 480 | 50 | 8 / 16 | |||
| 18.F5.K0H-360F | |||||||
| 19.F5.K1H-350F | 30 | 3 x 380… 480 | 60 | 4 / 16 | |||
| 19.F5.K0H-350F | |||||||
| 20.F5.K1H-340F | 37 | 3 x 380… 480 | 75 | 2 / 8 | |||
| 20.F5.K0H-340F | |||||||
| 20.F5.K1/3R-960A | 37 | 3 x 380… 480 | 75 | 8 / 16 | |||
| 20.F5.K0/2R-960A | |||||||
| 21.F5.K1/3R-950A | 45 | 3 x 380… 480 | 90 | 4 / 16 | |||
| 21.F5.K0/2R-950A | |||||||
| 22.F5.K1/3R-950A | 55 | 3 x 380… 480 | 115 | 4 / 16 | |||
| 22.F5.K0/2R-950A | |||||||
| 23.F5.K1/3R-940A | 75 | 3 x 380… 480 | 150 | 2 / 12 | |||
| 23.F5.K0/2R-940A | |||||||
| 23.F5.K1U-960A | 75 | 3 x 380… 480 | 150 | 8 | |||
| 23.F5.K0U-960A | |||||||
| 24.F5.K1R-940A | 90 | 3 x 380… 480 | 180 | 2 / 8 | |||
| 24.F5.K0R-940A | |||||||
| 24.F5.K1U-950A | 90 | 3 x 380… 480 | 180 | 4 / 16 | |||
| 24.F5.K0U-950A | |||||||
| 25.F5.K1U-910A | 110 | 3 x 380… 480 | 210 | 4 / 8 | |||
| 25.F5.K0U-910A | |||||||
| 26.F5.K1U-910A | 132 | 3 x 380… 480 | 250 | 4 / 8 | |||
| 26.F5.K0U-910A | |||||||
| 27.F5.K1U-900A | 160 | 3 x 380… 480 | 300 | 2 / 8 | |||
| 27.F5.K0U-900A | |||||||
| 28.F5.K1W-900A | 200 | 3 x 380… 480 | 370 | 2 / 4 | |||
| 28.F5.K0W-900A | |||||||
| 29.F5.K1W-900A | 250 | 3 x 380… 480 | 460 | 2 | |||
| 29.F5.K0W-900A | |||||||
| 30.F5.K1W-A00A | 315 | 3 x 380… 480 | 570 | 2 | |||
| 30.F5.K0W-A00A | |||||||
| 31.F5.K1W-A00D | 355 | 3 x 380… 480 | 630 | 2 | |||
| 31.F5.K0W-A00D | |||||||
| 32.F5.K1W-A00D | 400 | 3 x 380… 480 | 710 | 2 | |||
| 32.F5.K0W-A00D | |||||||
| EXTRA CHARGE for feedback interfaces (in addition to the unit price) | |||||||
| interface kit | function CH2 | unit variant | Incremental encoder (CH1) | ||||
| 1M.F5.K81-GZ18 | IGR input TTL | – xxGx | D- and E- housing | ||||
| 1M.F5.K81-DZ19 | IGR output TTL | – xxDx | |||||
| 1M.F5.K81-4Z15 | SSI – Multiturn | – xx4x | TTL- signal level | ||||
| 2M.F5.K81-GZ18 | IGR input TTL | – xxGx | G- to W- housing | 5 V DC | |||
| 2M.F5.K81-DZ19 | IGR output TTL | – xxDx | |||||
| 2M.F5.K81-4Z15 | SSI – Multiturn | – xx4x | |||||
| 2M.F5.K81-AZ07 | Initiator | – xxAx | |||||
| 2M.F5.K81-7Z09 | Tacho | – xx7x | |||||
| 1M.F5.K81-KZ16 | IGR input TTL | – xxKx | D- and E- housing | HTL- signal level | |||
| 1M.F5.K81-JZ17 | IGR output TTL | – xxJx | push-pull or linear driver | ||||
| 2M.F5.K81-KZ16 | IGR input TTL | – xxKx | G- to W- housing | i.e. encoder with | |||
| 2M.F5.K81-JZ17 | IGR output TTL | – xxJx | inverse signals | ||||
| 1M.F5.K81-WZ08 | IGR input TTL | – xxWx | D- and E- housing | HTL- signal level | |||
| 1M.F5.K81-XZ09 | IGR output TTL | – xxXx | with invers signal | ||||
| 2M.F5.K81-WZ08 | IGR input TTL | – xxWx | G- to W- housing | 15/ 24 V DC | |||
| 2M.F5.K81-XZ09 | IGR output TTL | – xxXx | |||||
| 1M.F5.K81-TZ18 | IGR input TTL | – xxTx | D- and E- housing | HTL- signal level | |||
| 1M.F5.K81-SZ19 | IGR output TTL | – xxSx | 15/ 24 V DC | ||||
| 2M.F5.K81-TZ18 | IGR input TTL | – xxTx | G- to W- housing | without invers signal | |||
| 2M.F5.K81-SZ19 | IGR output TTL | – xxSx | |||||
| 1M.F5.K81-HZ28 | IGR input TTL | – xxHx | D- and E- housing | Resolver (CH1) | |||
| 1M.F5.K81-EZ29 | IGR output TTL | – xxEx | |||||
| 2M.F5.K81-HZ28 | IGR input TTL | – xxHx | G- to W- housing | ||||
| 2M.F5.K81-EZ29 | IGR output TTL | – xxEx | |||||
| 1M.F5.K8G-IZ48 | IGR input TTL | – xxIx | D- and E- housing | Hiperface (CH1) | |||
| 1M.F5.K8G-FZ49 | IGR output TTL | – xxFx | |||||
| 2M.F5.K8G-IZ38 | IGR input TTL | – xxIx | G- to W- housing | ||||
| 2M.F5.K8G-FZ39 | IGR output TTL | – xxFx | |||||
| 1M.F5.K8G-QZ42 | IGR input TTL | – xxQx | D- and E- housing | EnDat (CH1) | |||
| 1M.F5.K8G-PZ43 | IGR output TTL | – xxPx | |||||
| 1M.F5.K8G-3Z40 | SSI input | – xx3x | |||||
| 2M.F5.K8G-QZ32 | IGR input TTL | – xxQx | G- to W- housing | ||||
| 2M.F5.K8G-PZ33 | IGR output TTL | – xxPx | |||||
| 2M.F5.K8G-3Z30 | SSI input | – xx3x | |||||
| 1M.F5.K8G-9Z09 | IGR output TTL | – xx9x | D- and E- housing | BISS and | |||
| 2M.F5.K8G-9Z09 | IGR output TTL | – xx9x | G- to W- housing | EnDat 2.2 (CH1) | |||
| 1M.F5.K8G-NZ55 | IGR input TTL | – xxNx | D- and E- housing | SinCos (CH1) | |||
| 1M.F5.K8G-MZ56 | IGR output TTL | – xxMx | |||||
| 1M.F5.K8G-1Z51 | SSI input | – xx1x | |||||
| 2M.F5.K8G-NZ35 | IGR input TTL | – xxNx | G- to W- housing | ||||
| 2M.F5.K8G-MZ36 | IGR output TTL | – xxMx | |||||
| 2M.F5.K8G-1Z31 | SSI input | – xx1x | |||||
| 1M.F5.K8G-UZ44 | IGR input TTL | – xxUx | D- and E- housing | 7) SinCos- SSI (CH1) | |||
| 1M.F5.K8G-VZ47 | IGR output TTL | – xxVx | |||||
| 2M.F5.K8G-UZ34 | IGR input TTL | – xxUx | G- to W- housing | ||||
| 2M.F5.K8G-VZ37 | IGR output TTL | – xxVx | |||||
| 1M.F5.K8G-ZZ08 | IGR input TTL | D- and E- housing | 8) UVW (CH1) | ||||
| 2M.F5.K8G-ZZ08 | IGR input TTL | G- to W- housing | |||||
| KEB COMBIVERT F5 – options | |||||||
| part number | designation | features | |||||
| 00.F5.060-K000 | LCD- Operator | grafic display; keypad; SD card reader | |||||
| 00.F5.060-K010 | LCD-CAN-Interface- Operator | grafic display; keypad; RS 232/485; | |||||
| DIN 66019 II; 8MB memory; RTC; CAN | |||||||
| 00.F5.060-1000 | Digital- Operator | display; keypad | |||||
| 00.F5.060-2000 | Interface- Operator | display; keypad; RS 232/485; DIN 66019 II; HSP5 | |||||
| 00.F5.060-2100 | RS 485- Operator | RS 485; DIN 66019 II; Service HSP5 | |||||
| 00.F5.060-3000 | Profibus- Operator | display; keypad; Profibus-DP-Slave; Service HSP5 | |||||
| 00.F5.060-3100 | Profibus- Operator | Profibus-DP-Slave; Service HSP5 | |||||
| 00.F5.060-4000 | InterBus- Operator | display; keypad; InterBus Remote 500kB; Service HSP5 | |||||
| 00.F5.060-4001 | InterBus- Operator | display; keypad; InterBus Remote 2MB; Service HSP5 | |||||
| 00.F5.060-5010 | CAN- Operator | display; keypad; CANopen DS301+sync.; Service HSP5 | |||||
| 00.F5.060-5110 | CAN- Operator | CANopen DS301 + sync.; Service HSP5 | |||||
| 00.F5.060-6000 | SERCOS- Operator | display; keypad; FSMA- connect.; Service HSP5 | |||||
| 00.F5.060-7000 | DeviceNet- Operator | display; keypad; 5 pole terminal; Service HSP5 | |||||
| 00.F5.060-8000 | Ethernet- Operator | display; keypad; RJ45-connect.; Service HSP5 | |||||
| 00.F5.060-A000 | Modbus- Operator | display; keypad; Submin; Service HSP5 | |||||
| 00.F5.060-F000 | Ethercat- Operator | display; keypad; RJ45-connect.; Service HSP5 | |||||
| 00.F5.060-H000 | Powerlink- Operator | display; keypad; RJ45-connect.; Service HSP5 | |||||
| 00.F5.060-L100 | Profinet RT- Operator | without display;RJ45-connect.; Service HSP5 | |||||
| 00.F5.060-M100 | Ethernet IP- Operator | without display;RJ45-connect.; Service HSP5 | |||||
| 00.F5.060-9000 | HSP5/485- Operator | with Submin 15 pol.; for cable 00.F5.0C0-20xx | |||||
| 00.F5.060-9001 | HSP5/485- Operator | with 10 pole terminal; for cable 00.F5.0C0-30xx | |||||
| for external operator arrangement together with HSP5- Operator: | |||||||
| 00.F5.0C0- _030 | cable with SubminD L= 3 m | operator cable for external installation | |||||
| 00.F5.0C0- _050 | cable with SubminD L= 5 m | operator cable for external installation | |||||
| 00.F5.0C0- _100 | cable with SubminD L=10 m | operator cable for external installation | |||||
| F5 – instruments | |||||||
| 00.F5.025-0080 | PORT EXPANDER | USB-; Ethernet-; 4x HSP5-port; ext. 24V | |||||
| 00.F5.0C4-1010 | USB- Kabel | USB A-B; 4-pol.; l = 1 m | |||||
| 00.F5.0C0-4010 | cable RS 485/ HSP5 | connection RJ 45 – DSUB9; l = 1 m | |||||
| 00.F5.0C0-4020 | cable RS 485/ HSP5 | connection RJ 45 – DSUB9; l = 2 m | |||||
| 00.F5.0C0-4025 | cable RS 485/ HSP5 | connection RJ 45 – DSUB9; l = 2;5 m | |||||
| 00.F5.0C0-4050 | cable RS 485/ HSP5 | connection RJ 45 – DSUB9; l = 5 m | |||||
| 00.F5.0C0-0010 | Service cable HSP 5 | 1;8 m HSP 5 TTL- RS 232 / direct to inverter | |||||
| 00.F5.0C0-0020 | Fieldbus adapter HSP 5 | Dsub 9 / Western 400 mm | |||||
| 00.58.025-001D | COMBIVIS- cable | PC- connect. cable Sub9 RS 232 – 2;8m | |||||
| S7 – motion libary for F5 | |||||||
| 00.00.000-0660 | S7-Library- country licence | CD-ROM with function blocks for S7 | |||||
| single customer licence | only direct account from KEB-HQ | ||||||
| KEB COMBIVERT F5 – options EMC filter EN 55011 | |||||||
| HF – filter – kits | |||||||
| standard | standard (low leakage) |
IT-mains net | |||||
| max. motor cable length | 30 m | 10 m | 30 m | ||||
| size | Pn (kW) | U (V) | In (A) | part number | variant | variant | variant |
| housing B (230V) | submounted/external HF- filter EN 55011/B | ||||||
| 05.F5. | 0;37 | 1x230V | 2;3 | 07.U5.B0B- … | – | … -1010 | |
| 07.F5. | 0;75 | 1x230V | 4 | 07.U5.B0B- … | – | … -1010 | |
| 09.F5. | 1;5 | 1x230V | 7 | 10.U5.B0B- … | … -1000 | … -1010 | |
| 10.F5. | 2;2 | 1x230V | 10 | 10.U5.B0B- … | … -1000 | … -1010 | |
| 05.F5. | 0;37 | 3x230V | 2;3 | 07.U5.B0B- … | … -2000 | … -2010 | |
| 07.F5. | 0;75 | 3x230V | 4 | 07.U5.B0B- … | … -2000 | … -2010 | |
| 09.F5. | 1;5 | 3x230V | 7 | 10.U5.B0B- … | … -2000 | … -2010 | |
| 10.F5. | 2;2 | 3x230V | 10 | 10.U5.B0B- … | … -2000 | … -2010 | |
| housing D | |||||||
| 09.F5. | 1;5 | 1x230V | 7 | 10.U5.B0D- … | … -1000 | … -1010 | |
| 10.F5. | 2;2 | 1x230V | 10 | 10.U5.B0D- … | … -1000 | … -1010 | |
| 09.F5. | 1;5 | 3x230V | 7 | 10.U5.B0D- … | … -2000 | … -2010 | … -2020 |
| 10.F5. | 2;2 | 3x230V | 10 | 10.U5.B0D- … | … -2000 | … -2010 | … -2020 |
| 12.F5. | 4 | 3x230V | 16;5 | 12.U5.B0D- … | … -2000 | … -2010 | … -2020 |
| housing E | |||||||
| 13.F5. | 5;5 | 3x230V | 24 | 13.U5.B0E- … | … -2000 | … -2010 | … -2020 |
| 14.F5. | 7;5 | 3x230V | 33 | 14.U5.B0E- … | … -2000 | … -2010 | … -2020 |
| housing G | |||||||
| 14.F5. | 7;5 | 3x230V | 33 | 14.U5.B0G- … | … -2000 | … -2010 | … -2020 |
| 15.F5. | 11 | 3x230V | 48 | 15.U5.B0G- … | … -2000 | … -2010 | … -2020 |
| housing H | |||||||
| 15.F5. | 11 | 3x230V | 48 | 15.U5.B0H- … | … -2000 | … -2010 | … -2020 |
| 16.F5. | 15 | 3x230V | 66 | 16.U5.B0H- … | … -2000 | … -2010 | … -2020 |
| housing B (400V) | submounted/external HF- filter EN 55011/B | ||||||
| 07.F5. | 0;75 | 3x400V | 2;6 | 10.U5.B0B- … | … -3000 | … -3010 | … -3020 |
| 09.F5. | 1;5 | 3x400V | 4;1 | 10.U5.B0B- … | … -3000 | … -3010 | … -3020 |
| 10.F5. | 2;2 | 3x400V | 5;8 | 10.U5.B0B- … | … -3000 | … -3010 | … -3020 |
| 12.F5. | 4 | 3x400V | 9;5 | 12.U5.B0B- … | … -3000 | … -3010 | … -3020 |
| housing D | |||||||
| 09.F5. | 1;5 | 3x400V | 4;1 | 10.U5.B0D- … | … -3000 | … -3010 | … -3020 |
| 10.F5. | 2;2 | 3x400V | 5;8 | 10.U5.B0D- … | … -3000 | … -3010 | … -3020 |
| 12.F5. | 4 | 3x400V | 9;5 | 13.U5.B0D- … | … -3000 | … -3010 | … -3020 |
| 13.F5. | 5;5 | 3x400V | 12 | 13.U5.B0D- … | … -3000 | … -3010 | … -3020 |
| 14.F5. | 7;5 | 3x400V | 16;5 | 14.U5.B0D- … | … -3000 | … -3010 | … -3020 |
| housing E | |||||||
| 14.F5. | 7;5 | 3x400V | 16;5 | 14.U5.B0E- … | … -3000 | … -3010 | … -3020 |
| 15.F5. | 11 | 3x400V | 24 | 15.U5.B0E- … | … -3000 | … -3010 | … -3020 |
| 16.F5. | 15 | 3x400V | 33 | 16.U5.B0E- … | … -3000 | … -3010 | … -3020 |
| KEB COMBIVERT F5 – options EMC filter EN 55011 | |||||||
| HF – filter – kits | |||||||
| specification | standard | IT-mains net | IT-mains net | ||||
| max. motor cable length | 30 m | 30 m | 10 m | ||||
| size | Pn (kW) | U (V) | In (A) | part number | variant | variant | variant |
| housing G | submounted/external HF- filter EN 55011/B | ||||||
| 16.F5. | 15 | 3x400V | 33 | 17.U5.B0G- … | … -3000 | … -3021 | … -3030 |
| 17.F5. | 18;5 | 3x400V | 40 | 17.U5.B0G- … | … -3000 | … -3021 | … -3030 |
| 18.F5. | 22 | 3x400V | 50 | 18.U5.B0G- … | … -3000 | … -3020 | … -3030 |
| 18.F5. | 22 | 3x400V | 50 | 18.U5.B0H- … | … -3000 | … -3020 | … -3030 |
| 19.F5. | 30 | 3x400V | 60 | 19.U5.B0H- … | … -3000 | … -3020 | … -3030 |
| 20.F5. | 30 | 3x400V | 75 | 20.U5.B0H- … | … -3000 | ||
| housing R | |||||||
| 19.F5. | 30 | 3x400V | 60 | 20.U5.B0R- … | … -3000 | ||
| 20.F5. | 37 | 3x400V | 75 | 20.U5.B0R- … | … -3000 | ||
| 21.F5. | 45 | 3x400V | 90 | 23.U5.B0R- … | … -3000 | ||
| 22.F5. | 55 | 3x400V | 115 | 23.U5.B0R- … | … -3000 | ||
| 23.F5. | 75 | 3x400V | 150 | 23.U5.B0R- … | … -3000 | ||
| 24.F5. | 90 | 3x400V | 180 | 25.U5.B0U- … | … -3000 | ||
| housing U | external HF- filter EN 55011/B | ||||||
| 23.F5. | 75 | 3x400V | 150 | 23.U5.B0U- … | … -3000 | ||
| 24.F5. | 90 | 3x400V | 180 | 25.U5.B0U- … | … -3000 | ||
| 25.F5. | 110 | 3x400V | 210 | 25.U5.B0U- … | … -3000 | ||
| 26.F5. | 132 | 3x400V | 250 | 27.U5.B0U- … | … -3000 | ||
| 27.F5. | 160 | 3x400V | 300 | 27.U5.B0U- … | … -3000 | ||
| External HF- filter acc. EN 55011-A | |||||||
| housing U | external HF- filter | ||||||
| 26.F5. | 132 | 3x400V | 250 | 26.U5. A0U- … | …-3000 | ||
| housing W | |||||||
| 28.F5. | 200 | 3x400V | 370 | 28.U5.A0W- … | …-3000 | ||
| 29.F5. | 250 | 3x400V | 460 | 30.U5.A0W- … | …-3000 | ||
| 30.F5. | 315 | 3x400V | 570 | 30.U5.A0W- … | …-3000 | ||
| 31.F5. | 355 | 3x400V | 32.U5.A0W- … | …-3000 | |||
| 32.F5. | 400 | 3x400V | 32.U5.A0W- … | …-3000 | |||
| NHF- filter – combination of EMC filter EN 55011/ level B and uk=4% choke – 400V class | |||||||
| PN(kW) | IN (A) | dimension (L x W x H) in mm | |||||
| 13.E5.T60-1011 | 5;5 | 14 | 290 x 82 x 200 | ||||
| 14.E5.T60-1011 | 7;5 | 19 | 340 x 100 x 210 | ||||
| 15.E5.T60-1011 | 11 | 27 | 340 x 100 x 210 | ||||
| 16.E5.T60-1011 | 15 | 37 | 340 x 100 x 210 | ||||
| 17.E5.T60-1011 | 18;5 | 47 | 340 x 110 x 210 | ||||
| 18.E5.T60-1011 | 22 | 55 | 340 x 110 x 210 | ||||
| 19.E5.T60-1011 | 30 | 66 | 340 x 110 x 210 | ||||
„